web analytics

Cisco CCNP Data Center 642-997 Dumps With VCE and PDF Download (Question 76 – Question 80)

New 642-997 exam questions from PassLeader 642-997 dumps! Welcome to download the newest PassLeader 642-997 VCE and PDF dumps: http://www.passleader.com/642-997.html (137 Q&As)

P.S. Free 642-997 dumps are available on Google Drive shared by PassLeader: https://drive.google.com/open?id=0B-ob6L_QjGLpS1BYSmhLTVRyeTg

QUESTION 76
passleader-642-997-dumps-761
passleader-642-997-dumps-762
passleader-642-997-dumps-763
passleader-642-997-dumps-764
Customer has configured FabricPath allocate-delay to 600. What is the effect of this?

A.    The allocate-delay is the time for FP to go Into forwarding state
B.    It specifies the time delay for a transitioned value to be propagated throughout the network
C.    It specifies the time delay for a link bringup to detect conflicts
D.    The allocate-delay is the time delay for a new resource to be propagated throughout the network

Answer: D
Explanation:
Specifies the time delay for a new resource to be propagated throughout the network.
http://www.cisco.com/web/techdoc/dc/reference/cli/nxos/commands/fpath/fabricpath_timers.html

QUESTION 77
Hotspot Question
passleader-642-997-dumps-771
passleader-642-997-dumps-772
passleader-642-997-dumps-773
passleader-642-997-dumps-774
FabricPath switch-id is 25 and load-balance is configured for L3/L4 and rotate amount is 14 byte. What information is true about FabricPath switch-id?

A.    FabricPath topology requires manual configuration of switch-id which has a range from 1 to 4095
B.    Every FabricPath must have a manually configured switch-id for it to form a FabricPath topology
C.    FabricPath topology requires manual configuration of switch-id which has a range from 1 to 4099
D.    You do not have to manually assign a switch ID unless you are running a virtual port channel plus (vPC*) because the system assigns a switch ID for you when you enable FabricPath

Answer: D
Explanation:
FabricPath switch-id (vPC)
To configure a virtual port channel plus (vPC+) switch ID, use the FabricPath switch-id command. To remove the FabricPath switch from a vPC domain, use the no form of this command.
fabricpath switch-id switch-id
no fabricpath switch-id [ switch-id ]
Usage Guidelines
You do not have to manually assign a switch ID (unless you are running a vPC+); the system assigns a switch ID for you when you enable FabricPath.
Note You must assign the same vPC+ switch ID to each of the two vPC+ peer devices before they can form an adjacency.
This command requires an Enhanced Layer 2 license.
Examples:
This example shows how to configure a vPC+ switch ID on a FabricPath-enabled device:
switch# configure terminal
switch(config)# vpc domain 1
switch(config-vpc-domain)# fabricpath switch-id 1
Configuring fabricpath switch id will flap vPCs. Continue (yes/no)? [no]

QUESTION 78
Hotspot Question
passleader-642-997-dumps-781
passleader-642-997-dumps-782
passleader-642-997-dumps-783
What is the status of FCoE license on Cisco Nexus 5548 switch?

A.    FCoE license is not installed
B.    FCoE license is installed, but it is expired
C.    FCoE license is installed and status is enabled
D.    FCoE license does not need to be installed because it is part of ENTERPRISE_PKG

Answer: A

QUESTION 79
Hotspot Question
passleader-642-997-dumps-791
passleader-642-997-dumps-792
passleader-642-997-dumps-793
Ethernet interface 1/5 on Cisco Nexus 5548 is connected to Cisco UCB C220 rack server. What is the status of Ethernet 1/5 interface for FCoE functionality?

A.    Interface reset on Ethernet 1/5 is preventing the FCoE connection from coming up
B.    MTU size of 1500 on Ethernet interface 1/5 needs to be changed for FCoE to come UP
C.    Cisco Nexus 5548 needs a layer 3 daughter card for FCoE to come UP on the Ethernet interface 1/5
D.    Ethernet interface 1/5 is operational for FCoE and the status is UP

Answer: D

QUESTION 80
Hotspot Question
passleader-642-997-dumps-801
passleader-642-997-dumps-802
passleader-642-997-dumps-803
What is the status of FC interface associated with ethernet 1/5 indicate?

A.    Trunk VSAN 11 is isolated
B.    Interface vfc 5 is up and running for the assigned VSAN
C.    Trunk VSAN 11 is initializing
D.    VSAN to FC mapping is not working as expected

Answer: B


New 642-997 exam questions from PassLeader 642-997 dumps! Welcome to download the newest PassLeader 642-997 VCE and PDF dumps: http://www.passleader.com/642-997.html (137 Q&As)

P.S. Free 642-997 dumps are available on Google Drive shared by PassLeader: https://drive.google.com/open?id=0B-ob6L_QjGLpS1BYSmhLTVRyeTg